Combined display of all available logs of Appropedia. You can narrow down the view by selecting a log type, the username (case-sensitive), or the affected page (also case-sensitive).
- 21:01, 10 November 2019 Biomedkitchen talk contribs uploaded File:Red-Beast-2p0-dimension.jpg
- 20:39, 10 November 2019 Biomedkitchen talk contribs uploaded a new version of File:Red-Beast-2p0-fluid-couplings.JPG (Second version of the water cooler, high-pressure fluid couplings. Image by biomedkitchen.)
- 20:20, 10 November 2019 Biomedkitchen talk contribs uploaded File:Red-Beast-2p0-fluid-couplings.JPG (Second version of the water cooler, high-pressure fluid couplings. Image by biomedkitchen.)
- 20:18, 10 November 2019 Biomedkitchen talk contribs uploaded File:Red-Beast-2p0.JPG (Second version of the water cooler, with a new heat exchanger and fhigh-pressure fluid couplings. Image by biomedkitchen.)
- 05:54, 8 November 2019 Biomedkitchen talk contribs uploaded File:Offline-cooling-setup-1p2kW-2kL-1p0.png (This shows the setup for offline cooling for dialysis pre-treatment, including an RO system. The trend in stored water temperature when cooled offline using a 2 kL tank and a 1.2 kW heat exchanger. Diagram by biomedkitchen.)
- 05:52, 8 November 2019 Biomedkitchen talk contribs uploaded File:Offline-cooling-model-2p5kW-2kL-1p0.png (This shows the trend in stored water temperature when cooled offline using a 2 kL tank and a 2.5 kW heat exchanger. Diagram by biomedkitchen.)
- 05:51, 8 November 2019 Biomedkitchen talk contribs uploaded File:Offline-cooling-model-2p5kW-1kL-1p0.png (This shows the trend in stored water temperature when cooled offline using a 1 kL tank and a 2.5 kW heat exchanger. Diagram by biomedkitchen.)
- 05:50, 8 November 2019 Biomedkitchen talk contribs uploaded File:Offline-cooling-model-1p2kW-2kL-1p0.png (This shows the trend in stored water temperature when cooled offline using a 2 kL tank and a 1.2 kW heat exchanger. Diagram by biomedkitchen.)
- 05:49, 8 November 2019 Biomedkitchen talk contribs uploaded File:Offline-cooling-model-1p2kW-1kL-1p0.png (This shows the trend in stored water temperature when cooled offline using a 1 kL tank and a 1.2 kW heat exchanger. Diagram by biomedkitchen.)
- 05:17, 8 November 2019 Biomedkitchen talk contribs uploaded File:Water-cooler-spec1.png (This is the basic principle of cooling water prior to RO treatment for dialysis.)
- 21:02, 7 November 2019 Biomedkitchen talk contribs uploaded File:Red-Beast-1p0.jpg (This is the first prototype built to test the concept of on-line cooling.)
- 20:18, 29 September 2019 User account Biomedkitchen talk contribs was created